Cost performance optimization analysis of glue inj

2022-06-20
  • Detail

Cost performance optimization analysis of glue injection and strip threading insulation technology system in recent years, the scope of national power rationing has been further expanded, which has sounded an alarm for us The continuous introduction of the national building energy conservation policy also makes us see the hope of realizing energy conservation At the same time, we also see another phenomenon With the deepening of the state's policy of effectively controlling housing prices, China's housing prices have begun to move towards stability The cost of heat insulation and energy-saving aluminum windows is bound to be higher than that of ordinary aluminum windows. We began to hear about the contradiction between energy-saving windows and doors and stabilizing house prices Is it really difficult to control the cost performance of insulated aluminum windows? What are the main differences between the glue injection insulation system from the United States and the strip insulation system from Europe

recently, there have been many issues surrounding us, two of which require our special attention First, the number of new generating units put into operation in 2005 will be between 68.4 million and 70 million kilowatts, and the electricity consumption of the whole society will reach 2422 billion kilowatt hours. The biggest gap in the annual power supply will reach 23 million kilowatts, significantly lower than last year In the existing power consumption structure, the power consumption of air conditioning in summer accounts for one third The second is the government's many control policies on the phenomenon of excessive growth of housing prices in the country We see that the government has made building energy conservation the top priority of national development For real estate developers and door, window and curtain wall companies, an efficient and energy-saving door, window and curtain wall insulation technology with moderate cost should be the best choice

there are two main heat insulation aluminum door and window technologies in the current construction market One is the strip insulation technology from Europe, and the other is the glue injection insulation technology from North America At present, the "heat and cold bridge technology" generally refers to the strip insulation technology Most people do not understand the characteristics of the glue injection heat insulation technology In fact, both glue injection and strip threading belong to the category of "heat cut and cold bridge technology" The technical prototype of glue injection insulation technology was born in the United States as early as 1937 In the 1970s, the leading rubber sleeve insulation aluminum production line was introduced from Hong Kong to Guangdong, China Therefore, the glue injection heat insulation technology is not unfamiliar to us

so, are all the heat insulation and energy-saving aluminum windows and curtain walls energy-saving products with heat insulation performance but high cost? Is it true that with the continuous adjustment of house prices, thermal insulation aluminum windows and curtain wall products will be carefully selected by developers? Our answer is No Both the "energy saving star" program of the United States and the "low interest loan building door and window energy saving program" led by the Ministry of construction and industry of Japan have been designated to use glue injection heat insulation technology This fully shows that the glue injection heat insulation technology is an advanced structural heat insulation technology that meets the international building energy saving standards and has moderate cost

next, we will analyze the difference between the glue injection heat insulation technology and the strip through heat insulation technology from several points

I. thermal insulation performance

for thermal insulation aluminum, the K value of thermal insulation material has a crucial impact on the thermal insulation performance of the whole aluminum material The K value of thermal insulation glue, the core of glue injection thermal insulation aluminum material, is 0.12 The K value of pa66+ air (or strip filler) in the core of strip insulation aluminum material is larger than that of insulation adhesive As a result, the U value of glued insulation aluminum materials and insulation doors and windows is lower than that of strip insulation aluminum materials and insulation doors and windows In China, we use these two different thermal insulation design structures to make the same 45mm internal opening window (1500mm × 1500mm), and the thermal insulation performance is simulated and analyzed by using American professional calculation software therm and windows It can be seen from the infrared analysis and test results of the thermodynamic properties of the two types of heat insulation windows that the heat insulation performance of the glue injected heat insulation windows is significantly better than that of the strip type heat insulation windows on the premise that the width of the door and window profiles, the configuration of the glass system and the width of the heat insulation materials are the same

finally, we found that the width of the strip insulation material is at least 4mm larger than that of the glue injection insulation material under the condition that the heat insulation performance of the two heat insulation windows is the same This feature provides a way for users to reduce the cost of doors and windows while keeping the heat insulation performance of doors and windows unchanged

II. Cost of door and window profiles

from the thermal insulation performance analysis just now, we can find that on the premise that the width of door and window profiles, the glass system configuration and the width of thermal insulation materials are the same, the bank should reduce the door sill. The thermal insulation performance of glue injection thermal insulation windows is significantly better than that of strip type thermal insulation windows Does better insulation mean higher material costs? The answer is No We have selected two kinds of products with the same frame width and the same insulation material width in China that can reach the second level of molding; The conditions are mild and the profile design is analyzed below

from the above two structural designs, it can be seen that due to the difference in the design dimensions of the glue injection insulation structure and the strip through insulation structure, the aluminum cavity dimension a is at least 4mm smaller than that of B Thus, on the premise of the same cavity design and the same wall thickness, the meter weight of the glued insulation aluminum is less than that of the threaded insulation aluminum For insulated aluminum windows with the same design and insulating glass configuration, the weight of glue injection insulated aluminum windows is much lower than that of strip type insulated aluminum windows

for the unit price per square meter of insulated aluminum window, weight is a crucial item Because the weight of the glue injection type heat insulation aluminum window is lower than that of the strip type heat insulation aluminum window, its cost price is also much lower than that of the strip type heat insulation aluminum window

we use 1500mm × The size of 1500mm standard sample window is analyzed and priced. It is found that the cost of aluminum material per square meter of glue injection type heat insulation window is about 20% lower than that of strip type heat insulation window This cost price can basically meet the requirements for the majority of users to meet the national heat insulation performance index (k value or U value) on the premise that the cost of aluminum windows does not increase much

III. profile strength (composite moment of inertia)

one of the keys to whether thermal insulation aluminum can be used as the main bearing heavy load body for windows or curtain walls of large and high-rise buildings is whether the strength (or composite moment of inertia) of thermal insulation aluminum can meet the requirements of the designer So, is the strength of glued insulation aluminum, threaded insulation aluminum and ordinary aluminum equal? We have also calculated and analyzed it We refer to the relevant EU standards (prEN 14024:2000 performance requirements and test of thermal insulation metal profiles) and the relevant American standards (AAMA TIR a8:2004 structural performance and analysis of aluminum alloy profiles for thermal insulation buildings) In order to fairly consider the strength difference of thermal insulation aluminum, we use the EU prEN 14024:2000 standard as the theoretical basis for calculation and analysis The following is part of the original translation of the standard:

calculation method of effective moment of inertia of thermal insulation profile

b.1 the deflection of thermal insulation profile can be calculated by common deflection formula, but the combined moment of inertia of elastic combination of metal profile shall be considered

b.2 the calculation formula of effective moment of inertia is:

ief = is · (1-)/(1- · C) (1)

where is = i1+ I2 + A1 12 +a2 22 (2)

v= (A1 12 + A2 22)/is (3)

c= λ 2/(π2+ λ 2) (4)

(5)

where: IEF - effective moment of inertia (unit: CM4)

is -- rigid moment of inertia (unit: CM4)

v -- combined parameter of rigid moment of inertia

c - elastic binding parameter

λ——— Geometric parameters

l - span of beam (unit: cm)

c -- elastic constant or combined elastic value of thermal insulation material (unit: n/mm2)

e - elastic modulus of aluminum alloy (unit: n/mm2)

a1 -- sectional area of A1 area (unit: cm2)

a2 -- sectional area of A2 area (unit: cm2)

1 - distance from the centroid of zone A1 to the centroid of heat insulation profile (unit: cm)

2 - distance from the centroid of A2 area to the centroid of heat insulation profile (unit: cm)

i1 - moment of inertia of profile in zone A1 (unit: CM4)

i2 - moment of inertia of profile in A2 area (unit: CM4)

note: 1) because λ It depends on the span of the beam, so the effective moment of inertia is a function of the span For large span, its value is close to the rigidity value

2) the formula of C is strictly valid for sinusoidal load, and has high accuracy for constant load and triangular load

b.3 calculation example:

area a1=253.7mm2

a2=336.3mm2

centroid distance a1=27.3mm

a2=25.2mm

moment of inertia i1=12570.2 mm4

then is=i1+i2+a12+a2a22 =12570.2+114422.0+253.7 × 27.32+336.3 × 25.22=529636.2 mm4

υ= (A1a12+A2a22)/IS =(253.7 × 27.32+336.3 × 25.22)/5 hot fried graphene battery in the first array 29636.2= 0.76

λ 2 =ca2 l2/[(EIS) υ (1 - υ)]

take the beam span of l=1000mm, the elastic constant of thermal insulation adhesive c=1600n/mm2, and the elastic modulus of aluminum alloy e=70000 n/mm2

λ 2 = 1600 × fifty-two point five two × 10002/[70000 × five hundred and twenty-nine thousand six hundred and thirty-six point two × zero point seven six × (.76)]

= 652.14

C= λ 2/(π2+ λ 2) =652.14/(3.142+652.14) =0.99

so the combined moment of inertia of the profile section:

ief=iso (1- υ)/(1- υ oC)

=529636.2 × (.76)/(.76 × 0.99) =513379.2 mm4

if the thermal insulation adhesive is regarded as aluminum alloy, the I value calculated by computer is 549217.4 MM4, which is basically close to the calculation result when the beam span is l=1000mm. The larger the span is, the more accurate the calculation result is

similarly, we have also made calculation and analysis for the threaded insulation aluminum material with the same structural size Because the main parameter C (elastic constant or combined elastic value of thermal insulation material) is far from each other, and the other related parameters are slightly different, the composite inertia distance of the two kinds of thermal insulation aluminum materials is quite different The specific results are shown in the figure:

IV Example of thermal insulation curtain wall design

acrotower center building (Korea)

acrotower center building is located in Seoul, Korea The building is located in Seoul's most famous central business district The whole complex consists of a 48 - storey building and a 64 - storey building For the design and requirements of the building complex, the architect requires that the width of the visible surface shall not exceed 80mm except that the curtain wall materials can withstand high wind pressure For this demanding requirement, the technical consulting company of the project proposed the AZON thermal insulation technical scheme as shown in the figure below After the performance calibration of Korea engineering test center, the scheme can meet the design requirements and cost standards of Party A

we don't want to see any unqualified products with potential safety hazards in Chinese buildings We recommend that users always put quality and safety first when choosing materials for building doors, windows and curtain walls

Copyright © 2011 JIN SHI